Search
You searched for:
Start Over
Photos
Remove constraint Photos
Subject
Drainage pipes
Remove constraint Subject: Drainage pipes
« Previous | 21 - 30 of 31 | Next »
Search Results
-
21. [Image] Closed Drain Construction - Tule Lake Sump 3 - Specs. No. 200C-842, Patterson Constr. Co., Contractor
P12-200-2910NA Klamath Project - Oregon-California. View of trencher starting to excavate a drain line. The hopper and digging unit are dropped into place at the outlet of the proposed line. Then, the ...Citation -
22. [Image] Closed Drain Construction - Tule Lake Sump 3 - Specs. No. 200C-842, Patterson Constr. Co., Contractor
P12-200-2917NA Klamath Project - Oregon-California. View of trenching equipment. The trencher is almost at the end of a newly installed closed drain line. Note the workman threading a short section of ...Citation -
23. [Image] Closed Drain Construction - Tule Lake Sump 3 - Specs. No. 200C-842, Patterson Constr. Co., Contractor
P12-200-2918NA Klamath Project - Oregon-California. View of digging and hopper unit being raised out of the open trench at the end of a completed drain line; November 1972; Bureau of Reclamation photo ...Citation -
24. [Image] Closed Drain Construction - Tule Lake Sump 3 - Specs. No. 200C-842, Patterson Constr. Co., Contractor
P12-200-2919NA Klamath Project - Oregon-California. View of pipe trenching equipment in operation; November 1972; Bureau of Reclamation photo by D. W. SteinCitation -
25. [Image] Closed Drain Construction - Tule Lake Sump 3 - Specs. No. 200C-842, Patterson Constr. Co., Contractor
P12-200-2920NA Klamath Project - Oregon-California. Inspector Derrill Stein is shown in foreground. He is watching the construction operation to see that the work performed by the contractor meets the ...Citation -
26. [Image] Closed Drain Construction - Tule Lake Sump 3 - Specs. No. 200C-842, Patterson Constr. Co., Contractor
P12-200-2921NA Klamath Project - Oregon-California. Side view of trenching equipment in operation. Note how the plastic drainage tubing is stretched out in advance of the trenching machine; November ...Citation -
27. [Image] Closed Drain Construction - Tule Lake Sump 3 - Specs. No. 200C-842, Patterson Constr. Co., Contractor
P12-200-2928NA Klamath Project - Oregon-California. View of contractor's workers threading plastic drainage tubing into hopper unit; November 1972; Bureau of Reclamation photo by D. W. SteinCitation -
28. [Image] Closed Drain Construction - Tule Lake Sump 3 - Specs. No. 200C-842, Patterson Constr. Co., Contractor
P12-200-2931NA Klamath Project - Oregon-California. Rear-end view of hopper unit. Pipe is fed out of the round hole at the bottom and cinders are placed around the pipe as it is being extruded from the ...Citation -
29. [Image] Closed Drain Construction - Tule Lake Sump 3 - Specs. No. 200C-842, Patterson Constr. Co., Contractor
P12-200-2932NA Klamath Project - Oregon-California. View of open trench before it was backfilled. The drainage tubing and cinder envelope are already in place; December 1972; Bureau of Reclamation ...Citation -
30. [Image] Closed Drain Construction - Tule Lake Sump 3 - Specs. No. 200C-842, Patterson Constr. Co., Contractor
P12-200-2938NA Klamath Project - Oregon-California. View of pipe laying and trenching equipment taken from down in the trench; December 1972; Bureau of Reclamation photo by D. W. SteinCitation